如何正确校准 Hach 浊度计

哈希浊度计是一种通过确定水中悬浮颗粒量来测量水透明度的重要工具。为了确保结果准确可靠,定期校准浊度计非常重要。校准是调整仪器以确保其提供准确读数的过程。在本文中,我们将指导您完成正确校准 Hach 浊度计的步骤。

型号 NTU-1800在线浊度测试仪
范围 0-10/100/4000NTU或根据要求
显示 液晶屏
单位 南洋理工大学
DPI 0.01
准确度 ±5% FS
Repeatability ±1%
Power ≤3W
Power Supply AC 85V-265V±10% 50/60Hz or
DC 9~36V/0.5A
Working Environment Ambient temperature:0~50℃;
Relative humidity≤85%
Dimensions 160*80*135mm(Hanging) or 96*96mm(Embeded)
Communication 4~20mA and RS-485 communication (Modbus RTU)
Switched output Three-way relay,capacity 250VAC/5A

Before you begin the calibration process, it is important to gather all the necessary equipment. You will need a calibration standard solution, a clean beaker, a stirrer, and of course, your Hach turbidity meter. Make sure that the calibration standard solution is within its expiration date and that it has not been contaminated.

To start the calibration process, first, fill the clean beaker with the calibration standard solution. The solution should be at room temperature to ensure accurate results. Place the beaker on a flat surface and insert the turbidity meter probe into the solution. Make sure that the probe is fully submerged and that there are no air bubbles trapped around it.

alt-955

Next, turn on the turbidity meter and allow it to stabilize for a few minutes. This will ensure that the instrument is ready for calibration. Once the meter has stabilized, adjust the calibration knob or setting on the meter to match the value of the calibration standard solution. This can usually be done by turning a dial or pressing a button on the meter.

After adjusting the calibration setting, gently stir the calibration standard solution to ensure that it is well mixed. This will help to ensure that the turbidity meter is reading the true value of the solution. Allow the meter to stabilize once again before taking a reading.

Once the meter has stabilized, take a reading of the calibration standard solution. The reading should match the value of the calibration standard solution. If the reading is off, adjust the calibration setting on the meter until it Matches the value of the solution.

After calibrating the turbidity meter, rinse the probe with clean water to remove any residue from the calibration standard solution. This will help to prevent contamination of future readings. Store the turbidity meter in a clean, dry place when not in use to ensure its longevity and accuracy.

In conclusion, calibrating your Hach turbidity meter is essential to ensure accurate and reliable results. By following the steps outlined in this article, you can properly calibrate your turbidity meter and maintain its accuracy over time. Regular calibration will help to ensure that your measurements are precise and that you can trust the results provided by your Hach turbidity meter.