Electrical transformers play a crucial role in the distribution of electricity, converting high voltage electricity into lower voltage Levels suitable for use in homes and businesses. One common type of transformer is the ground mounted transformer, which is installed on the ground rather than on a pole. These transformers offer a range of benefits compared to their pole-mounted counterparts, making them a popular choice for many utility companies and industrial facilities.
model | Rating\\u00a0power\\u00a0\\uff08KVA\\uff09 | Voltage\\u00a0combination\\uff08KV\\uff09 | No-load\\u00a0losses\\uff08W\\uff09 | Load\\u00a0losses\\uff08W\\uff09 | No-load\\u00a0current\\u00a0\\uff08%\\uff09 | Short-circuit\\u00a0voltage\\u00a0\\uff08%\\uff09 |
SC10-800 | 800 | 33,35,38/6,6.3,6.6,10,11 | 2200 | 9400 | 1.1 | 6.0 |
SC10-1000 | 1000 | Voltage\\u00a0combination\\uff08KV\\uff09 | 2610 | 10800 | 1.1 | 6.0 |
SC10-1250 | 1250 | 6,6.3,6.6,10,11/0.4 | 3060 | 11900 | 1.0 | 6.0 |
SC10-1500 | 1500 | Voltage\\u00a0combination\\uff08KV\\uff09 | 3600 | 15400 | 1.0 | 6.0 |
SC10-2000 | 2000 | 6,6.3,6.6,10,11/0.4 | 4130 | 18200 | 0.9 | 7.0 |
SC10-2500 | 2500 | Voltage\\u00a0combination\\uff08KV\\uff09 | 4750 | 21800 | 0.9 | 7.0 |
SC10-3150 | 3150 | 6,6.3,6.6,10,11/0.4 | 5880 | 24500 | 0.8 | 8.0 |
SC10-4000 | 4000 | Voltage\\u00a0combination\\uff08KV\\uff09 | 6860 | 29400 | 0.8 | 8.0 |
SC10-5000 | 5000 | 6,6.3,6.6,10,11/0.4 | 8180 | 34960 | 0.7 | 8.0 |
SC10-6300 | 6300 | Voltage\\u00a0combination\\uff08KV\\uff09 | 9680 | 40800 | 0.7 | 8.0 |
SC10-8000 | 8000 | 6,6.3,6.6,10,11/0.4 | 11000 | 46060 | 0.6 | 9.0 |
SC10-10000 | 10000 | Voltage\\u00a0combination\\uff08KV\\uff09 | 12660 | 56500 | 0.6 | 9.0 |
SC10-12500 | 12500 | 6,6.3,6.6,10,11/0.4 | 15400 | 64600 | 0.5 | 9.0 |
SC10-16000 | 16000 | Voltage\\u00a0combination\\uff08KV\\uff09 | 18900 | 76000 | 0.5 | 9.0 |
SC10-20000 | 20000 | 6,6.3,6.6,10,11/0.4 | 22400 | 85500 | 0.4 | 10.0 |
One of the key advantages of ground mounted transformers is their ease of access for maintenance and repairs. Because they are installed at ground level, technicians can easily access the transformer for routine inspections and repairs without the need for specialized equipment or climbing poles. This can help reduce downtime and ensure that the transformer remains in optimal working condition, ultimately improving the reliability of the electrical system.
Type | Rating\\u00a0power\\u00a0\\uff08KVA\\uff09 | Off-load\\u00a0losses\\uff08W\\uff09 | Voltage\\u00a0combination\\u00a0\\uff08KV\\uff09 | Load\\u00a0losses\\uff08W\\uff09 | Off-load\\u00a0current\\u00a0\\uff08%\\uff09 | Short-circuit\\u00a0impedance\\u00a0\\uff08%\\uff09 |
S11-M-30 | 30 | 100 | 6,6.3,10,10.5,11/0.4 | 600 | 2.3 | 4.0 |
S11-M-50 | 50 | 130 | 6,6.3,10,10.5,11/0.4 | 870 | 2.0 | 4.0 |
S11-M-63 | 63 | 150 | 6,6.3,10,10.5,11/0.4 | 1040 | 1.9 | 4.0 |
S11-M-80 | 80 | 180 | 6,6.3,10,10.5,11/0.4 | 1250 | 1.9 | 4.0 |
S11-M-100 | 100 | 200 | 6,6.3,10,10.5,11/0.4 | 1500 | 1.8 | 4.0 |
S11-M-125 | 125 | 240 | 6,6.3,10,10.5,11/0.4 | 1800 | 1.7 | 4.0 |
S11-M-160 | 160 | 280 | 6,6.3,10,10.5,11/0.4 | 2200 | 1.6 | 4.0 |
S11-M-200 | 200 | 340 | 6,6.3,10,10.5,11/0.4 | 2600 | 1.5 | 4.0 |
S11-M-250 | 250 | 400 | 6,6.3,10,10.5,11/0.4 | 3050 | 1.4 | 4.0 |
S11-M-315 | 315 | 480 | 6,6.3,10,10.5,11/0.4 | 3650 | 1.4 | 4.0 |
S11-M-400 | 400 | 570 | 6,6.3,10,10.5,11/0.4 | 4300 | 1.3 | 4.0 |
S11-M-500 | 500 | 680 | 6,6.3,10,10.5,11/0.4 | 5100 | 1.2 | 4.0 |
S11-M-630 | 630 | 810 | 6,6.3,10,10.5,11/0.4 | 6200 | 1.1 | 4.5 |
S11-M-800 | 800 | 980 | 6,6.3,10,10.5,11/0.4 | 7500 | 1.0 | 4.5 |
S11-M-1000 | 1000 | 1150 | 6,6.3,10,10.5,11/0.4 | 10300 | 1.0 | 4.5 |
S11-M-1250 | 1250 | 1360 | 6,6.3,10,10.5,11/0.4 | 12800 | 0.9 | 4.5 |
S11-M-1600 | 1600 | 1640 | 6,6.3,10,10.5,11/0.4 | 14500 | 0.8 | 4.5 |
S11-M-2000 | 2000 | 2280 | 6,6.3,10,10.5,11/0.4 | 17820 | 0.6 | 5.0 |
S11-M-2500 | 2500 | 2700 | 6,6.3,10,10.5,11/0.4 | 20700 | 0.6 | 5.0 |
S11-M-30- | 30 | 90 | 20,22/0.4 | 660 | 2.1 | 5.5 |
S11-M-50- | 50 | 130 | 20,22/0.4 | 960 | 2 | 5.5 |
S11-M-63- | 63 | 150 | 20,22/0.4 | 1145 | 1.9 | 5.5 |
S11-M-80- | 80 | 180 | 20,22/0.4 | 1370 | 1.8 | 5.5 |
S11-M-100- | 100 | 200 | 20,22/0.4 | 1650 | 1.6 | 5.5 |
S11-M-125- | 125 | 240 | 20,22/0.4 | 1980 | 1.5 | 5.5 |
S11-M-160- | 160 | 290 | 20,22/0.4 | 2420 | 1.4 | 5.5 |
S11-M-200- | 200 | 330 | 20,22/0.4 | 2860 | 1.3 | 5.5 |
S11-M-250- | 250 | 400 | 20,22/0.4 | 3350 | 1.2 | 5.5 |
S11-M-315- | 315 | 480 | 20,22/0.4 | 4010 | 1.1 | 5.5 |
S11-M-400- | 400 | 570 | 20,22/0.4 | 4730 | 1 | 5.5 |
S11-M-500 | 500 | 680 | 20,22/0.4 | 5660 | 1 | 5.5 |
S11-M-630 | 630 | 810 | 20,22/0.4 | 6820 | 0.9 | 6 |
S11-M-800 | 800 | 980 | 20,22/0.4 | 8250 | 1.8 | 6 |
S11-M-1000 | 1000 | 1150 | 20,22/0.4 | 11330 | 0.7 | 6 |
S11-M-1250 | 1250 | 1350 | 20,22/0.4 | 13200 | 0.7 | 6 |
S11-M-1600 | 1600 | 1630 | 20,22/0.4 | 15950 | 0.6 | 6 |
In addition to ease of access, ground mounted transformers also offer improved Safety compared to pole-mounted transformers. By being installed at ground level, there is less risk of accidents or injuries during maintenance and repairs. This can help protect both technicians and the general public from potential hazards associated with working at heights or in confined spaces.
Furthermore, ground mounted transformers are often more aesthetically pleasing than their pole-mounted counterparts. Because they are installed at ground level, they are less obtrusive and blend in more seamlessly with their surroundings. This can be particularly important in urban or residential areas where visual aesthetics are a concern.
One company in China that specializes in ground mounted transformers is offering their products at a discount. This company has a reputation for producing high-quality transformers that are reliable and efficient. By purchasing from this company, utility companies and industrial facilities can save money while still receiving a top-of-the-line product.
To showcase the benefits of their ground mounted transformers, the company has produced a series of informative videos. These videos highlight the features and advantages of their transformers, demonstrating how they can improve the efficiency and reliability of electrical systems. By watching these videos, potential customers can gain a better understanding of the benefits of ground mounted transformers and make an informed decision about whether they are the right choice for their needs.
In conclusion, ground mounted transformers offer a range of benefits compared to pole-mounted transformers. From ease of access and improved safety to enhanced aesthetics and cost savings, these transformers are a popular choice for many utility companies and industrial facilities. By purchasing from a reputable company in China that offers their products at a discount, customers can enjoy the advantages of ground mounted transformers while also saving money. Watching informative videos produced by the company can help potential customers better understand the benefits of ground mounted transformers and make an informed decision about their purchase.