Table of Contents
Understanding Electrical Transformers
Electrical transformers are vital components in power distribution systems, allowing for the efficient transfer of electrical energy between circuits. They operate on the principle of electromagnetic induction, converting high voltage electricity to a lower voltage, or vice versa, depending on the application. This transformation is crucial for the safe and effective delivery of electricity to homes and industries.

The design and construction of transformers involve careful consideration of materials and specifications to ensure reliability and performance. High-quality transformers, such as a 3150 kVA transformer, are built to withstand varying loads and environmental conditions, providing continuous power supply without interruptions. These devices are essential for maintaining voltage levels and ensuring that electrical equipment operates efficiently.
| Type | Rated capacity (KVA) | No-load losses(W) | Voltage combination (KV) | Load losses(W) | No-load current (%) | Short-circuit impedance (%) |
| S11-M-30 | 30 | 100 | 6,6.3,10,10.5,11/0.4 | 600 | 2.3 | 4.0 |
| S11-M-50 | 50 | 130 | 6,6.3,10,10.5,11/0.4 | 870 | 2.0 | 4.0 |
| S11-M-63 | 63 | 150 | 6,6.3,10,10.5,11/0.4 | 1040 | 1.9 | 4.0 |
| S11-M-80 | 80 | 180 | 6,6.3,10,10.5,11/0.4 | 1250 | 1.9 | 4.0 |
| S11-M-100 | 100 | 200 | 6,6.3,10,10.5,11/0.4 | 1500 | 1.8 | 4.0 |
| S11-M-125 | 125 | 240 | 6,6.3,10,10.5,11/0.4 | 1800 | 1.7 | 4.0 |
| S11-M-160 | 160 | 280 | 6,6.3,10,10.5,11/0.4 | 2200 | 1.6 | 4.0 |
| S11-M-200 | 200 | 340 | 6,6.3,10,10.5,11/0.4 | 2600 | 1.5 | 4.0 |
| S11-M-250 | 250 | 400 | 6,6.3,10,10.5,11/0.4 | 3050 | 1.4 | 4.0 |
| S11-M-315 | 315 | 480 | 6,6.3,10,10.5,11/0.4 | 3650 | 1.4 | 4.0 |
| S11-M-400 | 400 | 570 | 6,6.3,10,10.5,11/0.4 | 4300 | 1.3 | 4.0 |
| S11-M-500 | 500 | 680 | 6,6.3,10,10.5,11/0.4 | 5100 | 1.2 | 4.0 |
| S11-M-630 | 630 | 810 | 6,6.3,10,10.5,11/0.4 | 6200 | 1.1 | 4.5 |
| S11-M-800 | 800 | 980 | 6,6.3,10,10.5,11/0.4 | 7500 | 1.0 | 4.5 |
| S11-M-1000 | 1000 | 1150 | 6,6.3,10,10.5,11/0.4 | 10300 | 1.0 | 4.5 |
| S11-M-1250 | 1250 | 1360 | 6,6.3,10,10.5,11/0.4 | 12800 | 0.9 | 4.5 |
| S11-M-1600 | 1600 | 1640 | 6,6.3,10,10.5,11/0.4 | 14500 | 0.8 | 4.5 |
| S11-M-2000 | 2000 | 2280 | 6,6.3,10,10.5,11/0.4 | 17820 | 0.6 | 5.0 |
| S11-M-2500 | 2500 | 2700 | 6,6.3,10,10.5,11/0.4 | 20700 | 0.6 | 5.0 |
| S11-M-30- | 30 | 90 | 20,22/0.4 | 660 | 2.1 | 5.5 |
| S11-M-50- | 50 | 130 | 20,22/0.4 | 960 | 2 | 5.5 |
| S11-M-63- | 63 | 150 | 20,22/0.4 | 1145 | 1.9 | 5.5 |
| S11-M-80- | 80 | 180 | 20,22/0.4 | 1370 | 1.8 | 5.5 |
| S11-M-100- | 100 | 200 | 20,22/0.4 | 1650 | 1.6 | 5.5 |
| S11-M-125- | 125 | 240 | 20,22/0.4 | 1980 | 1.5 | 5.5 |
| S11-M-160- | 160 | 290 | 20,22/0.4 | 2420 | 1.4 | 5.5 |
| S11-M-200- | 200 | 330 | 20,22/0.4 | 2860 | 1.3 | 5.5 |
| S11-M-250- | 250 | 400 | 20,22/0.4 | 3350 | 1.2 | 5.5 |
| S11-M-315- | 315 | 480 | 20,22/0.4 | 4010 | 1.1 | 5.5 |
| S11-M-400- | 400 | 570 | 20,22/0.4 | 4730 | 1 | 5.5 |
| S11-M-500 | 500 | 680 | 20,22/0.4 | 5660 | 1 | 5.5 |
| S11-M-630 | 630 | 810 | 20,22/0.4 | 6820 | 0.9 | 6 |
| S11-M-800 | 800 | 980 | 20,22/0.4 | 8250 | 1.8 | 6 |
| S11-M-1000 | 1000 | 1150 | 20,22/0.4 | 11330 | 0.7 | 6 |
| S11-M-1250 | 1250 | 1350 | 20,22/0.4 | 13200 | 0.7 | 6 |
| S11-M-1600 | 1600 | 1630 | 20,22/0.4 | 15950 | 0.6 | 6 |
The 3150 kVA Transformer
| Type | Rated capacity (KVA) | Voltage combination(KV) | No-load losses(W) | Load losses(W) | No-load Current (%) | Short-circuit impedance (%) |
| SH15-M-30 | 30 | 6,6.3,10,10.5,11/0.4 | 33 | 630 | 1.50 | 4.0 |
| SH15-M-50 | 50 | 6,6.3,10,10.5,11/0.4 | 43 | 910 | 1.20 | 4.0 |
| SH15-M-63 | 63 | 6,6.3,10,10.5,11/0.4 | 50 | 1090 | 1.10 | 4.0 |
| SH15-M-80 | 80 | 6,6.3,10,10.5,11/0.4 | 60 | 1310 | 1.00 | 4.0 |
| SH15-M-100 | 100 | 6,6.3,10,10.5,11/0.4 | 75 | 1580 | 0.90 | 4.0 |
| SH15-M-125 | 125 | 6,6.3,10,10.5,11/0.4 | 85 | 1890 | 0.80 | 4.0 |
| SH15-M-160 | 160 | 6,6.3,10,10.5,11/0.4 | 100 | 2310 | 0.60 | 4.0 |
| SH15-M-200 | 200 | 6,6.3,10,10.5,11/0.4 | 120 | 2730 | 0.60 | 4.0 |
| SH15-M-250 | 250 | 6,6.3,10,10.5,11/0.4 | 140 | 3200 | 0.60 | 4.0 |
| SH15-M-315 | 315 | 6,6.3,10,10.5,11/0.4 | 170 | 3830 | 0.50 | 4.0 |
| SH15-M-400 | 400 | 6,6.3,10,10.5,11/0.4 | 200 | 4520 | 0.50 | 4.0 |
| SH15-M-500 | 500 | 6,6.3,10,10.5,11/0.4 | 240 | 5140 | 0.50 | 4.0 |
| SH15-M-630 | 630 | 6,6.3,10,10.5,11/0.4 | 320 | 6200 | 0.30 | 4.5 |
| SH15-M-800 | 800 | 6,6.3,10,10.5,11/0.4 | 380 | 7500 | 0.30 | 4.5 |
| SH15-M-1000 | 1000 | 6,6.3,10,10.5,11/0.4 | 450 | 10300 | 0.30 | 4.5 |
| SH15-M-1250 | 1250 | 6,6.3,10,10.5,11/0.4 | 530 | 12000 | 0.20 | 4.5 |
| SH15-M-1600 | 1600 | 6,6.3,10,10.5,11/0.4 | 630 | 14500 | 0.20 | 4.5 |
| SH15-M-2000 | 2000 | 6,6.3,10,10.5,11/0.4 | 750 | 18300 | 0.20 | 5.0 |
| SH15-M-2500 | 2500 | 6,6.3,10,10.5,11/0.4 | 900 | 21200 | 0.20 | 5.0 |
A 3150 kVA transformer is specifically designed to handle significant power loads, making it suitable for large industrial applications. This transformer type is capable of supplying power to multiple facilities or processes simultaneously, serving as a backbone for extensive electrical networks. Its robust design ensures durability and longevity, which are critical factors in industrial settings.
In China, manufacturers have embraced advanced technologies and quality control measures to produce high-performance transformers. These companies focus on using superior materials and cutting-edge manufacturing techniques, resulting in products that meet international standards. A 3150 kVA transformer from a reputable Chinese maker can offer excellent efficiency and reliability, catering to diverse energy needs.
Quality Assurance in Transformer Manufacturing
Quality assurance plays a pivotal role in the production of electrical transformers. Leading manufacturers implement stringent testing protocols throughout the manufacturing process to identify any potential issues before the transformers are deployed. This includes tests for insulation resistance, load capacity, and thermal stability, ensuring that every unit meets the required specifications.
<pFurthermore, ongoing research and development in transformer technology enable manufacturers to enhance the performance and efficiency of their products continually. Innovations such as improved cooling systems and advanced core materials contribute to reduced energy losses and better operational efficiency. A commitment to quality not only boosts the performance of a 3150 kVA transformer but also instills confidence in the end-users regarding safety and reliability.