Table of Contents
Understanding the Importance of Dissolved Oxygen Meter Specifications in Water Quality Monitoring
Understanding the Importance of Dissolved Oxygen Meter Specifications in Water Quality Monitoring
In the realm of water quality monitoring, the measurement of dissolved oxygen plays a crucial role in assessing the health and overall quality of aquatic ecosystems. Dissolved oxygen, often abbreviated as DO, refers to the amount of oxygen that is present in water. This parameter is vital for the survival of aquatic organisms, as it directly impacts their respiratory processes. As a result, accurate and reliable measurement of dissolved oxygen is essential for maintaining the balance and sustainability of aquatic environments.
Dissolved oxygen meters are the primary tools used to measure the concentration of oxygen in water. These devices come in various specifications, each designed to meet specific measurement requirements and environmental conditions. Understanding the specifications of these meters is essential for ensuring accurate and precise measurements, as well as for selecting the most suitable instrument for a given application.
One of the key specifications to consider when evaluating a dissolved oxygen meter is its measurement range. The measurement range indicates the minimum and maximum concentrations of dissolved oxygen that the meter can accurately detect. Choosing a meter with an appropriate measurement range is crucial for obtaining reliable data across a wide range of environmental conditions, from highly oxygenated waters to oxygen-depleted environments.
Another important specification to consider is the accuracy of the dissolved oxygen meter. Accuracy refers to the degree of closeness between the measured value and the true value of dissolved oxygen. A high level of accuracy is essential for obtaining reliable data, especially in critical applications such as environmental monitoring, aquaculture, and wastewater treatment. Additionally, the temperature range at which the meter operates is a crucial specification to consider, as it directly impacts the solubility of oxygen in water. Meters with a wider temperature range are capable of providing accurate measurements across varying thermal conditions, making them suitable for diverse aquatic environments.
Furthermore, the response time of a dissolved oxygen meter is a critical specification that directly influences its practical utility. Response time refers to the duration it takes for the meter to stabilize and provide a reliable measurement after being immersed in water. A fast response time is essential for obtaining real-time data and monitoring rapid changes in dissolved oxygen Levels, particularly in dynamic aquatic systems.
Calibration and maintenance requirements are also important specifications to consider when selecting a dissolved oxygen meter. Some meters may require frequent calibration to ensure accurate measurements, while others may feature self-calibration capabilities or longer calibration intervals. Understanding the calibration and maintenance needs of a meter is crucial for ensuring its long-term reliability and performance.
Measuring Method | N,N-Diethyl-1,4-phenylenediamine (DPD) spectrophotometry | |||
Model | CLA-7122 | CLA-7222 | CLA-7123 | CLA-7223 |
Inlet water channel | Single channel | Dual channel | Single channel | Dual channel\\u00a0 |
Measurement range | Total Chlorine : (0.0 \\uff5e 2.0)mg/L ,calculated as Cl2 ; | Total Chlorine : (0.5 \\uff5e10.0)mg/L ,calculated as Cl2 ; | ||
pH\\uff1a\\uff080-14\\uff09\\uff1btemperature\\uff1a\\uff080-100\\uff09\\u2103 | ||||
Accuracy | Free chlorine: \\u00b110% or 0.05mg/L (whichever is greater), calculated as Cl2; Total chlorine: \\u00b110% or 0.05mg/L (whichever is greater), calculated as Cl2 | Free chlorine: \\u00b110% or 0.25mg/L (whichever is greater), calculated as Cl2; Total chlorine: \\u00b110% or 0.25mg/L (whichever is greater), calculated as Cl2 | ||
pH:\\u00b10.1pH\\uff1bTemp.:\\u00b10.5\\u2103 | ||||
Measurement cycle | Free Chlorine\\u22642.5min | |||
Sampling interval | The interval (1\\uff5e999) min can be set to any value | |||
Maintenance cycle | Recommended once a month (see maintenance chapter) | |||
Environmental | Ventilated and dry room without strong vibration; Suggested room temperature: (15 \\uff5e 28)\\u2103; relative humidity: \\u226485% (no condensation). | |||
requirements | ||||
Sample water flow | \\uff08200-400\\uff09 mL/min | |||
inlet water pressure | \\uff080.1-0.3\\uff09 bar | |||
Inlet water temperature range | \\uff080-40\\uff09\\u2103 | |||
Power supply | AC (100-240)V\\uff1b 50/60Hz | |||
Consumption | 120W | |||
Power connection | 3-core power cord with plug is connected to the mains Socket with ground wire | |||
Data output | RS232/RS485/\\uff084\\uff5e20\\uff09mA | |||
Dimension size | H*W*D:\\uff08800*400*200\\uff09mm |