Comparing Dry Type and Liquid Filled Transformers

Transformers are essential components in electrical systems, as they help to regulate voltage Levels and ensure the safe and efficient distribution of electricity. When it comes to transformers, there are two main types that are commonly used: dry type transformers and liquid filled transformers. In this article, we will compare these two types of transformers and discuss their advantages and disadvantages.

Dry type transformers, as the name suggests, do not use any liquid for cooling or insulation. Instead, they rely on air to dissipate heat and provide insulation. This makes them a popular choice for indoor applications where the use of liquid-filled transformers may not be practical. Dry type transformers are also known for their low maintenance requirements and high efficiency. They are often used in commercial and industrial buildings, as well as in Renewable Energy systems such as solar and wind power plants.

On the other hand, liquid filled transformers use oil or other types of liquid as a cooling and insulation medium. This allows them to handle higher power levels and provide better insulation compared to dry type transformers. Liquid filled transformers are commonly used in outdoor applications, such as power substations and utility grids. They are also preferred in situations where the transformer needs to be located in a harsh Environment or subjected to high levels of electrical stress.

alt-965
One of the main advantages of dry type transformers is their Safety. Since they do not use any liquid, there is no risk of leakage or spillage, which can be a concern with liquid filled transformers. Dry type transformers are also more environmentally friendly, as they do not require the use of oil or other potentially hazardous liquids. In addition, dry type transformers are generally more compact and lightweight compared to liquid filled transformers, making them easier to install and transport.

However, dry type transformers also have some limitations. They are not suitable for high-power applications, as they may not be able to handle the heat generated by large electrical loads. In addition, dry type transformers may have a shorter lifespan compared to liquid filled transformers, as the lack of liquid cooling can Lead to higher operating temperatures and increased wear and tear on the transformer components.

Liquid filled transformers, on the other hand, are better suited for high-power applications and can handle larger electrical loads with ease. The use of liquid cooling also helps to extend the lifespan of the transformer and ensure reliable performance over time. However, liquid filled transformers are more expensive to purchase and maintain compared to dry type transformers. They also require regular monitoring and maintenance to ensure that the liquid levels are maintained and that there are no leaks or other issues that could affect the transformer’s performance.

Type Rated power (KVA) Voltage combination(KV) Off-load losses(W) Load losses(W) Off-load current (%) Short-circuit impedance (%)
SC12-30 30 6,6.3,6.6,10,11/0.4 150 710 2.0 4.0
SC12-50 50 6,6.3,6.6,10,11/0.4 215 1000 2.0 4.0
SC12-80 80 6,6.3,6.6,10,11/0.4 295 1380 1.5 4.0
SC12-100 100 6,6.3,6.6,10,11/0.4 320 1570 1.5 4.0
SC12-125 125 6,6.3,6.6,10,11/0.4 375 1850 1.3 4.0
SCB12-160 160 6,6.3,6.6,10,11/0.4 430 2130 1.3 4.0
SCB12-200 200 6,6.3,6.6,10,11/0.4 495 2530 1.1 4.0
SCB12-250 250 6,6.3,6.6,10,11/0.4 575 2760 1.1 4.0
SCB12-315 315 6,6.3,6.6,10,11/0.4 705 3470 1.0 4.0
SCB12-400 400 6,6.3,6.6,10,11/0.4 785 3990 1.0 4.0
SCB12-500 500 6,6.3,6.6,10,11/0.4 930 4880 1.0 4.0
SCB12-630 630 6,6.3,6.6,10,11/0.4 1070 5880 0.85 4.0
SCB12-630 630 6,6.3,6.6,10,11/0.4 1040 5960 0.85 6.0
SCB12-800 800 6,6.3,6.6,10,11/0.4 1210 6960 0.85 6.0
SCB12-1000 1000 6,6.3,6.6,10,11/0.4 1410 8130 0.85 6.0
SCB12-1250 1250 6,6.3,6.6,10,11/0.4 1670 9690 0.85 6.0
SCB12-1600 1600 6,6.3,6.6,10,11/0.4 1960 11700 0.85 6.0
SCB12-2000 2000 6,6.3,6.6,10,11/0.4 2440 14400 0.7 6.0
SCB12-2500 2500 6,6.3,6.6,10,11/0.4 2880 17100 0.7 6.0

In conclusion, both dry type and liquid filled transformers have their own set of advantages and disadvantages. The choice between the two types will depend on the specific requirements of the electrical system and the application in which the transformer will be used. It is important to carefully consider these factors and consult with a qualified electrical engineer or transformer supplier to determine the best type of transformer for your needs.